What Lights out after door ajar
actually means.
Sub-Zero undercounter units protect their cold by turning the interior lights off when a door has been left ajar. The lights stay off for a while even after the door closes. Sub-Zero asks owners to close the door and wait an hour before deciding the lights have failed.
Sub-Zero outdoor kitchen display · also shown as no interior light
What to do when Lights out after door ajar shows on the outdoor kitchenKind of codeDoor and drawer
The control thinks a door or a drawer is open, or it truly is: a door switch that stuck after rain, a cold drawer that no longer rolls fully shut on a rusted slide, a gasket torn or hardened by sun, or a hinge that has dropped on a door with a heavy stainless panel. Wiping the gasket, clearing anything caught in the opening and checking that the unit still sits level usually help; a switch, a slide or a new gasket is a visit.
Usually leads toOutdoor kitchen rust and seal repair
Rust, pitting and failed seals on outdoor stainless treated: gaskets, hinges, slides and screws replaced, and surfaces cleaned and passivated.
Shows up asOutdoor Kitchen Error Code on a Cooler, Ice Maker or Drawer
An outdoor kitchen error code shows as letters or numbers on a cooler display, a flashing light on an ice maker, or a blinking indicator on a warming drawer.
MakeSub-Zero
An outdoor Sub-Zero unit is looked at for what a patio does to it: heat on the toe kick, splashing water and salty or chlorinated air.
SourceSub-Zero UC undercounter refrigeration use and care guide (includes the outdoor limited warranty)
Sub-Zero UC-series and Designer (DEU) undercounter units, including outdoor models.
Before you book,
in this order.
Each step comes from Sub-Zero's own guidance for Lights out after door ajar on its outdoor kitchens. Follow it to the end: the last card says whether this is a visit.
Close the door firmly and leave it shut for one hour.
Open it after the hour and see whether the lights have returned.
If they are still out, book a visit, because Sub-Zero's LED lighting is replaced by a technician.
Still there?
It usually turns into outdoor kitchen rust and seal repair. Book with the code and the model number.
What not to do
Dark lights after an open door are a protective step, not a burned-out LED. They are also not Sabbath mode, which on Designer units does the opposite and keeps the lights on.
What you may
notice with it.
The outdoor kitchen problems Lights out after door ajar tends to arrive with. Answer these at the outdoor kitchen before anyone is booked.
All problemsWhere Lights out after door ajar usually leads
Outdoor kitchen rust and seal repair.
Sub-Zero
outdoor kitchens.
An outdoor Sub-Zero unit is looked at for what a patio does to it: heat on the toe kick, splashing water and salty or chlorinated air.
Sub-Zero outdoor kitchen repairMore Sub-Zero codes
Door and drawer on other makes
Outdoor kitchen cooler
An outdoor-rated refrigerator, cold drawer or kegerator built under the island counter, sealed and vented to keep drinks cold through patio heat, sun and blowing rain.
Outdoor ice maker
An outdoor-rated ice maker built into the island that turns a garden water line into clear cubes, with a drain or a drain pump beneath it and a sealed stainless cabinet.
In Sub-Zero's own words
The door may have been left ajar which has disabled the lights to eliminate excess heat.
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Sub-Zero UC-series and Designer (DEU) undercounter units, including outdoor models.
Sub-Zero Lights out after door ajar outdoor kitchen repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about Lights out after door ajar.
Can I clear Lights out after door ajar myself?
My Sub-Zero outdoor cooler went dark inside after a party. Why?
Can I change the LED in a Sub-Zero outdoor unit myself?
Does a dark Sub-Zero light mean it stopped cooling?
Back to your everyday
Still showing Lights out after door ajar?
A booking with a code gets further when it carries the code or light copied exactly, the model and serial from the plate, and a word on whether the unit still cools, lights or makes ice. With those three the office can match the probable part to your outdoor unit the same afternoon.