Wait for the makers' temperatures, not the calendar
Perlick starts its spring procedure only after the daily lows are back above the limits in its environmental table, the same numbers that told you to shut down in the fall. An outdoor ice maker has its own floor; Scotsman's outdoor model wants air of at least 50°F and incoming water of at least 40°F.
Burners can be checked any dry day, but it helps to do the whole island at once. The steps below run in the order we use on a startup visit, from gas to cold to ice.
Source: Perlick — G5 User Installation and Operation Manual (Form Z3023) — Spring start-up after daily lows are above the environmental limits: remove grille, vacuum the condensing unit, refit, clean, restore power; run 24 hours to stabilize before use; Scotsman — Installation and User's Manual, SCCG50/SCCP50 Outdoor Model — Minimum air 50°F and water 40°F; low bin is normal below 65°F; do not drain into a pool or onto the ground; RV antifreeze poured into the bin drain of pump models when winterizing
Clear the burner tubes before the first flame
Every side burner and power burner mixes gas with air in a short tube, the venturi, between the valve and the burner. It is dark, dry and sheltered, which is exactly what spiders and insects look for in a quiet season. The CPSC asks owners to check that tube for blockage at least once every year and to clear it with a pipe cleaner or a wire, pushing the debris through into the burner. Lynx asks for the burners, venturis, orifices and valves to be checked for obstructions at the start of each new season.
Why a web in a tube is more than a nuisance
A blocked tube does not just weaken the flame. Lynx warns that nests in the burners, venturis and orifices can send gas out of the front of the burner and start a fire behind the control panel. A burner that lights with a lazy yellow flame, puffs or roars back toward the knobs should be turned off and left off until the tube has been cleared.
Hoses, connections and the soap test
The CPSC checklist covers the rest of the gas path an owner can see:
- Look over hoses for cracks, brittleness, holes and sharp bends, and keep them away from hot surfaces and dripping grease.
- With the supply valve open and every burner off, brush a solution of equal parts water and liquid detergent on the connections.
- Growing bubbles mean a leak: turn the gas off and tighten the connection you reached.
- If bubbles return, close the cylinder valve or shutoff and do not light anything until it has been repaired.
Source: U.S. CPSC — Publication 467, safety checks and LP gas container tips — Check the venturi tube for insects and spiders at least once a year and clear it with a pipe cleaner or wire; inspect hoses; soapy solution of one part water to one part detergent at connections; close the valve and have it repaired if tightening fails; Lynx — Professional Series Care and Use / Installation Manual — Check burners, venturis, orifices and valves for obstructions at the start of each season; nests can send gas out of the front of the burner and cause a fire behind the control panel; check for leaks only with soap and water
Bringing the outdoor kitchen cooler back
Perlick's spring start-up is a short list, and it mirrors the shutdown in reverse:
True asks for the same 24 hours of running before anything goes in. If the unit spent the winter under a cover, take it off before powering up and let the cabinet dry, and keep planters, cushions and the folded cover itself clear of the front vents.
- Take off the front grille.
- Check the condensing unit for loose debris and vacuum it clean.
- Refit the grille.
- Clean the cabinet inside and out with stainless cleaner and polish.
- Restore power at the plug, the breaker or the master switch behind the grille.
- Let it cool to its set point and run for 24 hours to stabilize before use.
Source: Perlick — G5 User Installation and Operation Manual (Form Z3023) — Spring start-up after daily lows are above the environmental limits: remove grille, vacuum the condensing unit, refit, clean, restore power; run 24 hours to stabilize before use; True Residential — 15 and 24 Inch Undercounter Install Guide and User's Manual — Run the unit for 24 hours prior to usage to verify proper operation
The outdoor ice maker's first days
The water line that was disconnected at the inlet valve in the fall has to go back on, the supply valve opened and the connection watched for drips before the machine is switched on. Scotsman's outdoor manual describes the winter shutdown in detail and gives its cleaning and sanitizing procedure separately, so a machine that sat all winter is a good candidate for that cleaning before the first batch is kept.
Expect a slow start. Scotsman expects the bin to run low in air cooler than 65°F, so a thin bin on a cool April weekend is not a sign of trouble. Check that the drain still runs to its proper point and never into a pool or onto the lawn.
If antifreeze went into the drain in the fall
On drain pump models, the Scotsman winter procedure pours RV antifreeze into the bin drain. That fluid should be flushed through before the machine makes ice for drinks; if you are not sure how your model clears it, we can do the startup.
Source: Scotsman — Installation and User's Manual, SCCG50/SCCP50 Outdoor Model — Minimum air 50°F and water 40°F; low bin is normal below 65°F; do not drain into a pool or onto the ground; RV antifreeze poured into the bin drain of pump models when winterizing
Power, outlets and the warming drawer
Plug the warming drawer back in only once its cabinet and receptacle are dry. Alfresco wants that drawer's plug in a protected spot beneath the counter, ideally on a GFCI receptacle. If a GFCI trips as soon as something is plugged in after the winter, leave it off and treat it as a sign of moisture or damage rather than resetting it over and over.
Source: Alfresco — AXEWD-30 Warming Drawer Care and Use Manual — Receptacle under the counter away from the elements; GFCI receptacle recommended