A stone outdoor kitchen island on a sunny patio with the side burner grate lifted off and set on the counter beside a small nylon brush and a spray bottle of soapy water, the burner knobs all in the off position and no flame, the outdoor kitchen cooler door open on empty clean shelves, the cooking head closed and cropped at the far end, a lawn softly blurred behind.

Maintenance and prevention

Outdoor Kitchen Spring Startup: Burner Tubes, the Soap Test and a Day to Settle

An outdoor kitchen spring startup follows the makers' own order: wait until the air is back above each unit's lower limit, clear spiders and insects from the burner tubes and check hoses and connections with soapy water, clean the cooler's condenser and let it run 24 hours before stocking, and bring the ice maker back on its water line with the first batches checked.

(844) 449-0269

Mon–Sat, 8am–8pm

  • Habits that keep the island working for years
  • 5-minute read
  • Across every type and make

Book a visit

Three short steps, about a minute.

or call (844) 449-0269

At a
glance.

An island that sat quiet for months has had time to collect webs in its burner tubes, leaves in its cooler grille and a stiff hose or two. The first warm weekend is the moment to find them, before guests and a full cooler are waiting.

Read the whole guide

Burner tubesCheck for spiders and insects at least once a year

The CPSC and burner makers both ask for it.

Leak checkSoapy water on the connections, never a flame

Bubbles mean a leak; close the gas and book a visit.

Cold unitsRun 24 hours before stocking

Perlick and True both ask for a day to stabilize.

Ice makerLow output below 65°F air is normal

Scotsman's outdoor model manual says so.

Wait for the makers' temperatures, not the calendar

Perlick starts its spring procedure only after the daily lows are back above the limits in its environmental table, the same numbers that told you to shut down in the fall. An outdoor ice maker has its own floor; Scotsman's outdoor model wants air of at least 50°F and incoming water of at least 40°F.

Burners can be checked any dry day, but it helps to do the whole island at once. The steps below run in the order we use on a startup visit, from gas to cold to ice.

Source: Perlick — G5 User Installation and Operation Manual (Form Z3023) — Spring start-up after daily lows are above the environmental limits: remove grille, vacuum the condensing unit, refit, clean, restore power; run 24 hours to stabilize before use; Scotsman — Installation and User's Manual, SCCG50/SCCP50 Outdoor Model — Minimum air 50°F and water 40°F; low bin is normal below 65°F; do not drain into a pool or onto the ground; RV antifreeze poured into the bin drain of pump models when winterizing

Clear the burner tubes before the first flame

Every side burner and power burner mixes gas with air in a short tube, the venturi, between the valve and the burner. It is dark, dry and sheltered, which is exactly what spiders and insects look for in a quiet season. The CPSC asks owners to check that tube for blockage at least once every year and to clear it with a pipe cleaner or a wire, pushing the debris through into the burner. Lynx asks for the burners, venturis, orifices and valves to be checked for obstructions at the start of each new season.

Why a web in a tube is more than a nuisance

A blocked tube does not just weaken the flame. Lynx warns that nests in the burners, venturis and orifices can send gas out of the front of the burner and start a fire behind the control panel. A burner that lights with a lazy yellow flame, puffs or roars back toward the knobs should be turned off and left off until the tube has been cleared.

Hoses, connections and the soap test

The CPSC checklist covers the rest of the gas path an owner can see:

  • Look over hoses for cracks, brittleness, holes and sharp bends, and keep them away from hot surfaces and dripping grease.
  • With the supply valve open and every burner off, brush a solution of equal parts water and liquid detergent on the connections.
  • Growing bubbles mean a leak: turn the gas off and tighten the connection you reached.
  • If bubbles return, close the cylinder valve or shutoff and do not light anything until it has been repaired.

Source: U.S. CPSC — Publication 467, safety checks and LP gas container tips — Check the venturi tube for insects and spiders at least once a year and clear it with a pipe cleaner or wire; inspect hoses; soapy solution of one part water to one part detergent at connections; close the valve and have it repaired if tightening fails; Lynx — Professional Series Care and Use / Installation Manual — Check burners, venturis, orifices and valves for obstructions at the start of each season; nests can send gas out of the front of the burner and cause a fire behind the control panel; check for leaks only with soap and water

Close on a soft brush clearing leaves from the front grille of an outdoor kitchen cooler.
Close on a soft brush clearing leaves from the front grille of an outdoor kitchen cooler.

Bringing the outdoor kitchen cooler back

Perlick's spring start-up is a short list, and it mirrors the shutdown in reverse:

True asks for the same 24 hours of running before anything goes in. If the unit spent the winter under a cover, take it off before powering up and let the cabinet dry, and keep planters, cushions and the folded cover itself clear of the front vents.

  • Take off the front grille.
  • Check the condensing unit for loose debris and vacuum it clean.
  • Refit the grille.
  • Clean the cabinet inside and out with stainless cleaner and polish.
  • Restore power at the plug, the breaker or the master switch behind the grille.
  • Let it cool to its set point and run for 24 hours to stabilize before use.

Source: Perlick — G5 User Installation and Operation Manual (Form Z3023) — Spring start-up after daily lows are above the environmental limits: remove grille, vacuum the condensing unit, refit, clean, restore power; run 24 hours to stabilize before use; True Residential — 15 and 24 Inch Undercounter Install Guide and User's Manual — Run the unit for 24 hours prior to usage to verify proper operation

The outdoor ice maker's first days

The water line that was disconnected at the inlet valve in the fall has to go back on, the supply valve opened and the connection watched for drips before the machine is switched on. Scotsman's outdoor manual describes the winter shutdown in detail and gives its cleaning and sanitizing procedure separately, so a machine that sat all winter is a good candidate for that cleaning before the first batch is kept.

Expect a slow start. Scotsman expects the bin to run low in air cooler than 65°F, so a thin bin on a cool April weekend is not a sign of trouble. Check that the drain still runs to its proper point and never into a pool or onto the lawn.

If antifreeze went into the drain in the fall

On drain pump models, the Scotsman winter procedure pours RV antifreeze into the bin drain. That fluid should be flushed through before the machine makes ice for drinks; if you are not sure how your model clears it, we can do the startup.

Source: Scotsman — Installation and User's Manual, SCCG50/SCCP50 Outdoor Model — Minimum air 50°F and water 40°F; low bin is normal below 65°F; do not drain into a pool or onto the ground; RV antifreeze poured into the bin drain of pump models when winterizing

Power, outlets and the warming drawer

Plug the warming drawer back in only once its cabinet and receptacle are dry. Alfresco wants that drawer's plug in a protected spot beneath the counter, ideally on a GFCI receptacle. If a GFCI trips as soon as something is plugged in after the winter, leave it off and treat it as a sign of moisture or damage rather than resetting it over and over.

Source: Alfresco — AXEWD-30 Warming Drawer Care and Use Manual — Receptacle under the counter away from the elements; GFCI receptacle recommended

Step
by step.

Five steps, in the order worth doing them.

01

Check the forecast against each manual

Start once the nights stay above the lowest air temperature for every unit you plan to run.

02

Clear and inspect the gas side

Clean the burner tubes, look over the hoses and soap-test the connections with every burner off.

03

Clean and restart the cold units

Vacuum the condenser, clean the cabinet, restore power and wait 24 hours before stocking.

04

Reconnect and clean the ice maker

Refit the water line, check for drips, run the cleaning cycle and expect slow ice on cool days.

05

Bring the power back last

Plug in the warming drawer on a dry outlet and note any GFCI that trips.

A family gathered around an outdoor kitchen island on a sunny patio.
For the heart of your home.

Questions
owners ask.

How do I get spiders out of a side burner tube?
With the gas off and the burner cool, the CPSC suggests a pipe cleaner or a wire pushed through the tube toward the burner. If the burner has to come out to reach the tube and your manual does not show how, leave it for a technician.
Why does my outdoor kitchen cooler need a day before I stock it?
The cabinet and the air inside it need time to settle at the set point after months off. Both Perlick and True recommend 24 hours of running before use.
Is it normal for the outdoor ice maker to make little ice in spring?
On cool days, yes. Scotsman says a low bin is normal in air below 65°F. If output stays low once days are warm, the cause is worth a look.
What does an outdoor kitchen spring startup visit include?
We check the gas path from the supply to each burner, clear burner tubes, test the connections, clean and restart the cold units, reconnect and clean the ice maker and check the outlets and the warming drawer.

Back to your everyday

Read it and still not sure?